BCNDW - VICTORY FLOOR FINISH 596

  • MSDS: BCNDW
  • Manufacturer: CELLO CORP
  • Product Name: VICTORY FLOOR FINISH 596
  • National Stock Number: 7930-00N006604
Product Identification

Product ID:VICTORY FLOOR FINISH 596
MSDS Date:01/01/1985
FSC:7930
NIIN:00N006604
MSDS Number: BCNDW

Responsible Party
CELLO CORP

Emergency Phone: 301 939 1234

Cage: 02176

Contractor
CELLO CORP
HAVRE DE GRACE, MD 21078 US

Telephone: 410-939-1234

Cage: 02176

Ingredients

TRIBUTOXYETHYLPHOSPHATE

CAS: 78-51-3

RTECS: KJ9800000


POLYETHYLENE WAX

CAS: 9002-88-4

RTECS: TQ3325000


ZINC OXIDE

CAS: 1314-13-2

RTECS: ZH4810000

Fraction By Weight: 2.0%

OSHA PEL 15MG/M3 TDUST/5 FUME

ACGIH TLV: 10MG/M3 TDUST; 9293


STYRENE ACRYLIC POLYMER


DIETHYLENE GLYCOL MONOETHYLETHER

CAS: 111-90-0

RTECS: KK8750000

Hazards

Effects of Overexposure:EYE IRRIT. NO TOXIC EFT ON RESP SYSTEM.POSS
DRYING OF SKIN WHEN IN CONT FOR LONG PERIODS. SKIN DEFAT

First Aid

First Aid:EYES: FLUSH IMMED W/COPIOUS AMTS OF H*2O FOR @ LAST 15 MIN.
IF IRRIT PERSISTS CALL PHYSICIAN. SKIN: FLUSH OFF
W/H*2O.INGEST:INDUCE VOMIT ING. CALL PHYSICIAN.

Fire Fighting

Flash Point:NONFLAM, SCC
Extinguishing Media:N/A (MFR)

Accidental Release

Spill Release Procedures:ABSORB ONTO POROUS MATERIAL SUCH AS
SAWDUST/DIATOMACEOUS EARTH & DEPOSIT INTO CONTAINERS.

Handling

Handling and Storage Precautions:NORMAL GOOD HANDLING & HOUSEKEEPING
PRACTICES. STORE IN COOL AREA AWAY FROM ACIDS OR OXIDIZING AGENTS.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:NONE NEEDED (MFR)
Ventilation:LOCAL EXHAUST RECOMMENDED
Protective Gloves:NOT NECESSARY
Eye Protection:PROTECTIVE GLASSES
Other Protective Equipment:NONE
Supplemental Safety and Health
PH: 8.5 +- 0.2.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:190F
Vapor Pres:27
Spec Gravity:1.0324
Evaporation Rate & Reference:1 (H*2O)
Solubility in Water:COMPLETE
Appearance and Odor:WHITE MILKY LIQUID W/FAINT SWEET, ACRYLIC ODOR
Percent Volatiles by Volume:81

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS, STRONG OXIDANTS
Stability Condition to Avoid:EXTREMES OF TEMP
Hazardous Decomposition Products:CO, CO*2, ACRID FUMES, PHOSPHORUS
OXIDES

Disposal

Waste Disposal Methods:DISPOSE OF IN LANDFILL OR INCINERATE IAW LOCAL,
STATE & FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.